Pengaruh Variasi Evaporator Terhadap Unjuk Kerja Mesin Pendingin Menggunakan Refrigerant R134a

  • Suyanto Suyanto Universitas Ivet Semarang
  • Ari Setiawan

Abstract

Cooling machines are currently equipment that cannot be separated from human life. For this reason, a lot of research on cooling machines has been carried out to further optimize the work of the machine. This research was conducted to determine the effect of variations in the length of the evaporator pipe on the performance of the cooling machine. Evaporator pipes are varied with a length of 1 meter, 2 meters, and 3 meters. Other parameters are the length of the condenser pipe of 10 meters, the length of the capillary tube of 1.6 meters, and the freon pressure of 10Psi.  Based on the results of measurements and calculations of 3 types of evaporator pipe variations, it can be concluded that variations with 1 meter long evaporator pipe get the best results, namely with an average low temperature of 0,920C, a refrigeration effect of 113.53 kJ/kg, and a COP of 2.62.

References

Akhmad Syukri Maulana, Ary Bachtiar Khrisna Putra, (2015), Studi Eksperimen Variasi Beban Pendinginan pada Evaporator Mesin Pendingin Difusi Absorpsi R22-DMF, JURNAL TEKNIK ITS Vol. 4, No. 1

Alif Puspita Ningrum, D. L. 2016. Analisis Variasi Tipe Evaporator dengan Refrigeran LPG Terhadap Unjuk Kerja Mesin Refrigerator, Volume 9, Nomor 1, 49-54.

Hendri, Prayudi, Roswati Nurhasanah, (2014), Studi Eksperimental Pengaruh Temperatur Evaporasi Terhadap Unjuk Kerja Mesin Pendingin Dengan Refrigerant R134a dan MC134, Proceeding Seminar Nasional Tahunan Teknik Mesin XIII (SNTTM XIII) Depok, 15 – 16 Oktober 2014.

M. Almaududi, (2020), Pengaruh Laju Aliran Udara Masuk Evaporator Terhadap Kapasitas Pendinginan (Coefficient Of Performance) Dan Kelembapan Udara Pada Sistem Refrigerasi Air Condition, Edu Elektrika Journal Vol. 9 No. 1.

Nanang Rahayu, Rahmat Wahyudi (2015), Pengaruh Variasi Diameter Tube Pipa Evaporator dengan Circular Fins Terhadap Pressure Drop Aliran Refrigerant Pada Sistem Refrigerasi, Sinergi, Vol. 19, No. 1.

Ridwan, (2005), Perbandingan Unjuk Kerja Freon R-12 dan R 134a Terhadap variasi Beban Pendinginan pada Sistem Refrigerator 75W, Prosiding Seminar Nasional Tahunan Teknik Mesin IV, Universitas Udayana, Bali, 21-22 Nopember 2005.

Stoecker, Wilbert F., and Jones, Jerold W. 1982. Refrigerasi dan Pengkondisian Udara. Jakarta : Erlangga.
Published
2022-08-31
How to Cite
SUYANTO, Suyanto; SETIAWAN, Ari. Pengaruh Variasi Evaporator Terhadap Unjuk Kerja Mesin Pendingin Menggunakan Refrigerant R134a. Marine Science and Technology Journal, [S.l.], v. 3, n. 1, p. 12-18, aug. 2022. ISSN 2746-1580. Available at: <https://www.e-journal.ivet.ac.id/index.php/maristec/article/view/2245>. Date accessed: 06 july 2025. doi: https://doi.org/10.31331/maristec.v3i1.2245.